PF test under AC 220V and full loading
● Input voltage:95V~130V/170~250V
● Output voltage:12V
● Output power range:0~400W
● Power factor:PF>0.7
● Efficiency:90%
● Size:245*97*38mm
● Weight:1800g
● Certificates:CE,ROHS
● All round protection: OCP,OVP,OLP,OTP
● Customized: Input voltage/Output current/ Output voltage
● Warranty period:3 years
13717067602 19373029063
Technical parameter
Model |
SC-400W-12V |
|
OUTPUT |
Output Voltage |
12V DC |
Output Voltage Range |
12V DC士0.5V DC |
|
Output Current |
Max 33.33A |
|
Output Power |
Max 400w |
|
Output Power Range |
0-400w |
|
Ripple & Noise |
≤120mv |
|
Linear Regulation |
土1% |
|
Load Regulation |
土1% |
|
Start-up Time |
500 ms/230VAc 800ms/115VAC |
|
Hold Up Time |
100 ms/230VAc 100 ms/115VAC |
|
INPUT |
Input Voltage |
100V-264VAC |
Frequency |
50/60Hz |
|
Input Current |
4A ~1.6A |
|
Power Factor |
PF>0.7 |
|
No-Load Power Consumption |
<3w |
|
Efficiency |
89% |
|
Inrush current |
Cold Start 60A AT 230VAC |
|
Control Surge Capability |
L.N:2KV L.N-PE:4KV |
|
Leakage Current |
Max 0.5mA |
|
ENVIRONMENT |
Working Temperature |
ta :-30°C-50°C tc: 80°c |
Working Humidity |
20 ~ 99%RH,Condensing(Waterproof) |
|
Storage Temp, Humidity |
-40 C ~ 80 C, 10~95%RH |
|
PROTECTION |
Overtemperature |
Protection type:Turn off the output voltage, after the temperature drops, re-energize to restore. |
Overload protection |
Shut down the output when current load ≥110%-150%, auto recovers. |
|
Short Circuit Protection |
Protection type: It can be automatically restored after the fault is eliminated. |
|
SAFETY&EMC |
Withstand Voltage |
I/P-O/P:3750VAC |
Isolation Resistance |
I/P-O/P: 100MΩ/500VDC/25°C/70%RH |
|
Safety standards |
IEC/EN61347;IEC/EN60950;IP67 |
|
EMC Test Standards |
EN55015:2013;EN61547:2009; |
|
EN61000-3-2:2014; EN61000-3-3:2013 |
||
Reliability and Quality Control |
Impact aging |
100% of the product is fully loaded and impacted for 4 hours under an environment of at least 40°C±5°C |
Component Derating |
Under the steady-state conditions of rated input and output, the stress of components will not exceed its maximum nominal value |
|
NOTE |
1. All parameters not specifically mentioned are measured at 230VAC input, rated load and 25°C ambient temperature. 2. Ripple and noise test method: connect 0.1uF and 47uF capacitors in parallel at the terminal, and measure under 20MHZ bandwidth. 3. Ensure that the power supply is used under the rated parameters and environment. |
上一条:Ultra-thin constant voltage 12V 450W waterproof power supply